Roof Access Hatch Requirements

The ontario building code roof access 3 2 5 3.
Roof access hatch requirements. Nystrom roof hatches provide safe and convenient access to commercial building roof areas using interior ladders and stairs. In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5 m 2 in area and having a minimum dimension of 2 feet 610 mm. Grab bars not required at hatch exits. In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5m2 in area and having a minimum dimension.
1910 23 open roof hatches should be protected. A variety of special sizes are also available to provide an accessible way to install or remove large pieces of equipment from a building. 07 12 2000 1910 23 osha requires fall protection for elevator work when a fall hazard is present. All products feature engineered lift assistance for easy one hand operation.
They are present on most nonresidential buildings. A minimum perpendicular distance of 30 inches 76 cm from the centerline of the steps or rungs to the nearest object on the climbing side. Osha 1910 28 b 1 i 1910 23 a 4 ibc1015 7 roof access. Roof access for individuals often falls within this category.
Nystrom s complete line of roof hatch and safety products meet building codes fire and life safety requirements. Ideal for general maintenance and repairs on a roof these hatches are generally smaller starting from 600 x 600 as a minimum recommended size it is important to consider how the roof would be accessed at this size moving upwards towards the more recommended size of 900 x 750. Bilco roof hatches provide safe and convenient access to roof areas by means of an interior ladder ship stair or service stair. Where a stairway is provided to a roof access to the roof shall be provided through a penthouse complying with section 1509 2.
Or personal fall protection. Except as provided elsewhere in this section the employer must ensure that each employee on a walking working surface with an unprotected side or edge that is 4 feet 1 2 m or more above a lower level is protected from falling by one or more of the following. When unavoidable obstructions are encountered the minimum clearance at the obstruction may be reduced to 24 inches 61 cm provided deflector plates are installed see figure d 5 of this section. Roof access 1 on a building more than 3 storeys in building heightwhere the slope of the roof is less than 1 in 4 all main roof areas shall be provided with direct access from the floor areasimmediately below either by a a stairway or b a hatch not less than 550 mm by 900 mm with a fixed ladder.