Roof Anchor Installation Instructions

Reliable roofing is a professional commercial roofing contractor that can provide roof anchor installation services in lake zurich il and the north chicago suburbs.
Roof anchor installation instructions. If the material is not able to support 5 000 lbs. Installation guidelines for different slopes categories are listed below. More than one roof anchor is installed to a roof structure the strengths given in a or b above must be met at each roof anchors installation point independently. If two roof anchors are installed onto a roof structure each anchor location must be independently capable of supporting 5 000 lbs.
3 0 operation and use. Slopes 4 12 and more a lay out anchordeck synthetic roofing underlayment horizontally parallel to the eave with the printed side up. Not for use as an abseiling point. Continue adding panels until the roof is covered.
Lay flat cap nail flat. The silicone will spread and adhere creating a seal. Do not stretch during installation. Applied in any direction permitted by the restraint system when in use.
The roof material must be capable of supporting a minimum tensile load of 5 000 lbs. 2 way roof anchor installation instructions this product is part of a personal fall arrest system. Installation of this roof anchor must be certified by a qualified person or engineering service. B install anchordeck synthetic roofing underlayment without wrinkles.
Roof anchors can be as simple as a d ring connection or as complex as a complete lifeline system. Metal roofing is also available in the form of shingles. You may need to cut panels to fit angles using a circular saw with a metal saw blade. Anchor points are usually installed on the roof and are used to connect lanyards lifelines and other forms of tie off which prevent a worker from falling.
Minimum tensile load a qualified person must confirm that the support structure maintains a safety factor of two as per osha 1926 502. Install the panel so that the short lip overlaps the large lip. Roof anchors installed for restraint applications must be attached to a roof member capable of sustaining a static load of at least 3 000 lbs. Each roof anchor installation must be independently capable of sustaining this load.
In general roof anchors should be installed on roofs or structures that are made of wood and sheathing. Screw the new panel in place as described. Both permanent and temporary roof anchor points are available. During installation and assembly of the anchor device ensure that the installer is not less that 2 m from any edge or opening.